<
From version < 79.1 >
edited by Fredrik Lagerström
on 2020/03/18 11:44
To version < 79.2 >
edited by Fredrik Lagerström
on 2020/03/18 11:44
>
Change comment: (Autosaved)

Summary

Details

Page properties
Content
... ... @@ -276,40 +276,36 @@
276 276  Mesh and peak smoothing settings of **automatic finite element mesh generation**.
277 277  Perform gives additional features to **data safety**.
278 278  * **Analysis**
279 -In //Analysis// you can decide the way of [[(% class="wikiinternallink" %)**//Automatic save//**>>path:#Rules_of_time_save]](%%), in //Find identical copies before calculation for// you can// //set if the program should check the identical copies of structural elements and/or loads and in //Warnings //it can be checked if the program should warn about using non-linear elements in a linear calculation.
280 -
281 -
279 +In //Analysis// you can decide the way of **//Automatic save//**, in //Find identical copies before calculation for// you can// //set if the program should check the identical copies of structural elements and/or loads and in //Warnings //it can be checked if the program should warn about using non-linear elements in a linear calculation.
282 282  * **Result**
281 +//Options// define the calculation sections of bars and affect on **detailed results** of bars.
283 283  
284 -//Options// define the calculation sections of bars and affect on [[(% class="wikiinternallink" %)**detailed results**>>path:#_Detailed_Bar_Result]](%%) of bars.
283 +== Display ==
285 285  
285 +The current and default display settings of the drawing elements, numbers, **structural objects**, **loads** and **finite elements/mesh** can be set here.
286 286  
287 -==== Display ====
288 -
289 -
290 -The current and default display settings of the drawing elements, numbers, [[(% class="wikiinternallink" %)**structural objects**>>path:#_Structure_Definition]](%%), [[(% class="wikiinternallink" %)**loads**>>path:#_Loads]](%%) and [[(% class="wikiinternallink" %)**finite elements/mesh**>>path:#_Finite_Element_Mesh]](%%) can be set here.
291 -
292 292  Displaying structural and analytical element ID’s is separated in order to avoid duplicate labels on the screen. The required ID can be set by Bar and Shell elements in Display settings dialog.
293 293  
294 -[[image:file:///C:/Users/Fredrik/AppData/Local/Temp/msohtmlclip1/01/clip_image009.jpg]]
289 +[[image:1584527995499-252.png]]
295 295  
296 296  Figure: Display settings (Bar, Shell)
297 297  
298 -==== Window ====
293 +== Window ==
299 299  
300 300  
301 -//Co-ordinate systems// include the display settings of the //Global// and the //User-defined// (//UCS//) [[(% class="wikiinternallink" %)**co-ordinate system**>>path:#_Co-ordinate_Systems]](%%) symbols. The symbols are shown in the defined size in working windows, but they can be hidden by unchecking the //Display co-ordinate systems// box.
296 +//Co-ordinate systems// include the display settings of the //Global// and the //User-defined// (//UCS//) **co-ordinate system** symbols. The symbols are shown in the defined size in working windows, but they can be hidden by unchecking the //Display co-ordinate systems// box.
302 302  
303 -//Grid// defines the distribution settings of the visible [[(% class="wikiinternallink" %)**Construction grid**.>>path:#_Construction_grid]](%%) The grid can be hidden by unchecking the //Display grid// box. The grid lines can be set to be parallel with the axis directions of the //Global// (//Ground//) or //UCS// system.
298 +//Grid// defines the distribution settings of the visible **Construction grid**. The grid can be hidden by unchecking the //Display grid// box. The grid lines can be set to be parallel with the axis directions of the //Global// (//Ground//) or //UCS// system.
304 304  
305 -All default settings of [[(% class="wikiinternallink" %)**Object Snap tools**>>path:#_Object_Snap_Tools]](%%) are grouped in //Snap// dialog.
300 +All default settings of **Object Snap tools** are grouped in //Snap// dialog.
306 306  
307 307  In different windows different //scales// can be defined, which is especially useful in documentation module. By choosing an appropriate scale factor the displayed labels are easy to read. In another window the parameters can be decreased to highlight another result.
308 308  
309 309  //Units// setting offers various unit types for modeling (length, angle, force, mass and cross-sectional data) and for results. Stress and displacement units can be set independently of the length and force units.
310 310  
311 -[[image:file:///C:/Users/Fredrik/AppData/Local/Temp/msohtmlclip1/01/clip_image010.jpg]]
306 +[[image:1584528037251-456.png]]
312 312  
308 +
313 313  Figure: Available units
314 314  
315 315  = Data Safety =
... ... @@ -316,14 +316,15 @@
316 316  
317 317  Time saving and protection system ensures more the data safety of working files.
318 318  
319 -==== Time Save ====
315 +== Time Save ==
320 320  
321 -
322 322  FEM-Design automatically saves copy of the working file by given time period.
323 323  
324 324  The saving time period can be set in minutes at //Settings > All > Environment > General > System > Timesave//.
325 325  
326 -[[image:file:///C:/Users/Fredrik/AppData/Local/Temp/msohtmlclip1/01/clip_image011.png||alt="egerpad%20copy"]] Working on a project file called e.g. “steel construction.str” in the [[image:file:///C:/Users/Fredrik/AppData/Local/Temp/msohtmlclip1/01/clip_image012.png||alt="icon_3DSTRU"]] //3D Structure// module with a 15-minute time save period, an extra file will be generated and updated by the time period (0, 15, 30min …) with special extension and in a hidden folder:
321 +|(% style="width:98px" %)[[image:1584528146302-798.png]]|(% style="width:1352px" %)(((
322 +Working on a project file called e.g. “steel construction.str” in the [[image:1584528158180-507.png]] //3D Structure// module with a 15-minute time save period, an extra file will be generated and updated by the time period (0, 15, 30min …) with special extension and in a hidden folder:
323 +)))
327 327  
328 328  **Rules of time save:**
329 329  
... ... @@ -331,22 +331,22 @@
331 331  * If you successfully exit from FEM-Design after saving the current project, its time save copy will be erased from the recovery folder.
332 332  * The location of time save files cannot be modified for data safety.
333 333  
334 -**[[image:file:///C:/Users/Fredrik/AppData/Local/Temp/msohtmlclip1/01/clip_image003.wmz||alt="MCj04113200000%5b1%5d"]] **Additional automatic savings can be set before and after calculations at //Settings > Calculation > Analysis > Automatic save…//, but automatic savings overwrite the original project file.
331 +|(% style="width:99px" %)[[image:warning.png]]|(% style="width:1351px" %)(((
332 +Additional automatic savings can be set before and after calculations at //Settings > Calculation > Analysis > Automatic save…//, but automatic savings overwrite the original project file.
333 +)))
335 335  
336 -==== Recovery files ====
335 +== Recovery files ==
337 337  
338 -
339 339  Recovery file command in File menu is for managing time-save files which are generated after some unexpected events. Its tool-window:
340 340  
341 -[[image:file:///C:/Users/Fredrik/AppData/Local/Temp/msohtmlclip1/01/clip_image013.png]]
339 +[[image:1584528246118-584.png]]
342 342  
343 343  Figure: Recovery file dialog
344 344  
345 345  You can open the desired version and delete the useless ones, and you can also set the sorting criterion, by clicking on File / Date / Size.
346 346  
347 -==== Protected Work File ====
345 +== Protected Work File ==
348 348  
349 -
350 350  All working files are locked not to be modified, overwritten by another user or process. Starting a project, a file having the project name with **//.lck//** extension is generated automatically, which guarantees the protection till closing the working file.
351 351  
352 352  Opening a protected file sends the warning message: “//The file is locked by another user or process.//” You are allowed to open and modify the content of a protected file, but changes can be saved only under a new name (//File > Save as//).
Copyright 2020 StruSoft AB
FEM-Design Wiki